|
CFP STANDARD 2 - 8 ZONE CONVENTIONAL FIRE PANELS (TO EN54-2/4) |
|
|
CFP702-4 |
CFP Standard 2 zone panel, GD Systems branded code entry version,
does not extend |
118.45 |
|
CFP702-4U |
CFP Standard 2 zone panel, unbranded code entry version, does
not extend |
118.45 |
|
CFP702-4K |
CFP Standard 2 zone panel, GD Systems branded keyswitch version, does
not extend |
139.05 |
|
CFP702-4KU |
CFP Standard 2 zone panel, unbranded keyswitch version, does not
extend |
139.05 |
|
CFP704-4 |
CFP Standard 4 zone panel, GD Systems branded code entry version,
does not extend |
149.35 |
|
CFP704-4U |
CFP Standard 4 zone panel, unbranded code entry version, does
not extend |
149.35 |
|
CFP704-4K |
CFP Standard 4 zone panel, GD Systems branded keyswitch version, does
not extend |
169.95 |
|
CFP704-4KU |
CFP Standard 4 zone panel, unbranded keyswitch version, does not
extend |
169.95 |
|
CFP708-4 |
CFP Standard 8 zone panel, GD Systems branded code entry version,
does not extend |
226.60 |
|
CFP708-4U |
CFP Standard 8 zone panel, unbranded code entry version, does
not extend |
226.60 |
|
CFP708-4K |
CFP Standard 8 zone panel, GD Systems branded keyswitch version, does
not extend |
247.20 |
|
CFP708-4KU |
CFP Standard 8 zone panel, unbranded keyswitch version, does not
extend |
247.20 |
|
CFP760 |
CFP 8 zone repeater panel, GD Systems branded code entry version, max
8 per system |
172.24 |
|
CFP760U |
CFP 8 zone repeater panel, unbranded code entry version, max 8
per system |
172.24 |
|
CFP760K |
CFP 8 zone repeater panel, GD Systems branded keyswitch version, max
8 per system |
180.88 |
|
CFP760KU |
CFP 8 zone repeater panel, unbranded keyswitch version, max 8
per system |
180.88 |
|
CFP761 |
CFP network driver card, one required per repeater system, fit
at main |
60.34 |
|
CFP762 |
CFP relay output card, provides reset, fault, aux & remote relay
outputs |
40.99 |
|
CFP763 |
CFP relay output per zone card, as CFP762 plus 8 output per zone
relays |
63.19 |
|
CFP754/Z |
CFP 4 Zone Fire Alarm Starter Kit (Apollo version) |
291.26 |
| |
includes CFP704-4 panel, 2 x 1.2AHr batteries, C60 heat
detector/base, C60 smoke detector/base |
|
|
|
manual call point, 2 x sounders |
|
|
CFP754/W |
CFP 4 Zone Fire Alarm Starter Kit (System Sensor version) |
279.96 |
|
|
includes CFP704-4 panel, 2 x 1.2AHr batteries, C100 heat
detector/base, C100 smoke detector/base |
|
|
|
manual call point, 2 x sounders |
|
|
CFP754/N |
CFP 4 Zone Fire Alarm Starter Kit (Nittan version) |
294.76 |
|
|
includes CFP704-4 panel, 2 x 1.2AHr batteries, C120 heat
detector/base, C120 smoke detector/base |
|
|
|
manual call point, 2 x sounders |
|
|
|
|
|
|
CFP ECONOMY 2 - 8 ZONE CONVENTIONAL FIRE PANELS (TO EN54-2/4) |
|
|
Include all CFP standard features except coincidence, zone delay
and non-latching zone facilities |
|
|
CFP Economy panels are not compatible with CFP repeaters or CFP
relay boards |
|
|
CFP702E-4 |
CFP Economy 2 zone panel, code entry version, does not extend |
105.00 |
|
CFP702E-4K |
CFP Economy 2 zone panel, keyswitch version, does not extend |
110.00 |
|
CFP704E-4 |
CFP Economy 4 zone panel, code entry version, does not extend |
130.00 |
|
CFP704E-4K |
CFP Economy 4 zone panel, keyswitch version, does not extend |
135.00 |
|
CFP708E-4 |
CFP Economy 8 zone panel, code entry version, does not extend |
190.00 |
|
CFP708E-4K |
CFP Economy 8 zone panel, keyswitch version, does not extend |
195.00 |
|
|
|
|
|
CFP LPCB APPROVED 2 - 8 ZONE CONVENTIONAL FIRE PANELS (TO
EN54-2/4) |
|
|
Include all CFP standard features except coincidence and
non-latching zone facilities |
|
|
CFP702-4/LPC |
CFP LPCB approved 2 zone panel, code entry only, LPCB approved
to EN54-2/4, does not extend |
154.06 |
|
CFP704-4/LPC |
CFP LPCB approved 4 zone panel, code entry only, LPCB approved
to EN54-2/4, does not extend |
194.23 |
|
CFP708-4/LPC |
CFP LPCB approved 8 zone panel, code entry only, LPCB approved
to EN54-2/4, does not extend |
294.65 |
|
|
|
|
|
EFP SINGLE ZONE CONVENTIONAL FIRE PANELS (TO BS5839-4) |
|
|
EFP panels are not compatible with FP repeaters or FP relay
modules |
|
|
FF380-2 |
EFP1 single zone panel, does not extend |
85.43 |
|
FF380X |
EFPX expansion look and terminals for EFP1 |
2.71 |
|
BF378M |
MINIMUM miniature EOL module (for head out monitoring on EFP1) |
8.44 |
|
BF378 |
Electronic Monitoring Unit (for head out monitoring on EFP1) |
16.55 |
|
|
|
|
|
FP 2 - 14 ZONE CONVENTIONAL FIRE PANELS (TO BS5839-4) |
|
|
FF382-2 |
FP 2 zone panel, does not extend |
130.93 |
|
FF384-2 |
FP 4 zone panel, extends to 6 zones |
200.43 |
|
FF386-2 |
FP 6 zone panel, does not extend |
234.96 |
|
FF388-2 |
FP 8 zone panel, extends to 14 zones |
366.33 |
|
FF390-2 |
FP 10 zone panel, extends to 14 zones |
400.88 |
|
FF392-2 |
FP 12 zone panel, extends to 14 zones |
435.41 |
|
FF394-2 |
FP 14 zone panel, does not extend |
469.94 |
|
FF387Z-2 |
FP 2 zone extender pcb kit, use to extend FP panels |
34.54 |
|
BF378M |
MINIMUM miniature EOL module (for head out monitoring on EFP/FP) |
8.44 |
|
BF378 |
Electronic Monitoring Unit (for head out monitoring on EFP/FP) |
16.55 |
|
FF374FR |
FP fault relay module |
33.07 |
|
FF374DFR |
FP fire relay module |
33.07 |
|
FF374DT |
FP sounder delay module |
33.07 |
|
FF374X |
FPX expansion loom and terminals for use with FP 2-14 zone
panels |
10.99 |
|
FF396-2 |
FP 10 zone repeater panel |
125.06 |
|
FF398-2 |
FP 20 zone repeater panel |
187.62 |
|
FF379 |
Bezel for FP2 |
25.11 |
|
FF385 |
Bezel for FP4 / FP6 / FP Repeaters |
27.61 |
|
FF387 |
Bezel for FP8 / FP10 / FP12 / FP14 |
33.12 |
|
|
|
|
|
MFP 4 - 28 ZONE CONVENTIONAL FIRE PANELS (TO BS5839-4) |
|
|
FF504 |
MFP 4 zone microprocessor panel, extends to 12 zones |
231.18 |
|
FF508 |
MFP 8 zone microprocessor panel, extends to 12 zones |
333.52 |
|
FF512 |
MFP 12 zone microprocessor panel, does not extend |
435.84 |
|
FF516 |
MFP 16 zone microprocessor panel, extends to 28 zones |
633.46 |
|
FF520 |
MFP 20 zone microprocessor panel, extends to 28 zones |
735.80 |
|
FF524 |
MFP 24 zone microprocessor panel, extends to 28 zones |
838.13 |
|
FF528 |
MFP 28 zone microprocessor panel, does not extend |
940.47 |
|
FF501Z |
MFP 4 zone extender pcb kit, use to extend MFP panels |
102.32 |
|
FF574X |
MFPX expansion loom and terminals |
10.99 |
|
FF596 |
MFP 8 zone repeater panel, extends to 28 zones |
185.19 |
|
FF596R |
MFP 8 zone repeater extender kit, use to extend MFP repeaters |
41.55 |
|
FF596T |
Repeater transmitter pcb kit, one required per repeater system |
166.46 |
|
FF385 |
Bezel for MFP4 / MFP8 / MFP12 / MFP Repeaters |
27.61 |
|
FF387 |
Bezel for MFP16 / MFP20 / MFP24 / MFP28 |
33.12 |
|
|
|
|
|
FP AUTOMATIC EXTINGUISHER PANELS |
|
|
FF383H |
FP automatic extinguisher panel |
358.97 |
|
FF385 |
Bezel for FP automatic extinguisher panel |
27.61 |
|
|
|
|
|
REMOTE INDICATORS, RELAYS, DEVICE ISOLATORS AND SOUNDER CIRCUIT
EXTENDERS |
|
|
BF318 |
Remote LED indicator, supplied on a single gang plate |
5.68 |
|
|
Ideal for connecting to hidden or out of sight detectors or
directly to a sounder circuit |
|
|
BF376 |
24V 5A relay on a plate, supplied on a single gang plate |
17.18 |
|
|
Ideal for operating door retaining magnets, rollershutter doors
& other ancillary devices. |
|
|
|
Can switch mains or extra low voltages |
|
|
BF367 |
Auxillary device isolator, supplied on a single gang plate |
23.74 |
|
|
Allows a 24V d.c output from a fire panel to be remotely
isolated, ideal for preventing |
|
|
|
autodiallers, rollershutter doors etc, from accidentally
triggering during routine maintenance |
|
|
BF366 |
24V 5A isolatable relay on a plate, supplied on a single gang
plate |
35.00 |
|
|
Combines the functions of the BF376 5A relay and BF367 device
isolator in one unit |
|
|
FF502P |
Four zone monitored sounder extender, supplied on a double gang
plate |
41.55 |
|
|
Provides four extra sounder circuits with open and closed
circuit fault monitoring, two |
|
|
|
trigger inputs and one fault output |
|
|
|
|
|
|
24V POWER SUPPLIES |
|
|
BF375P |
24V 250mA unregulated door release PSU, supplied on a double
gang plate |
41.33 |
|
BF375PK |
24V 250mA unregulated door release PSU kit |
82.00 |
|
|
Includes one BF375P and one BF345/1H electromagnetic door
retainer |
|
|
BF375M |
24V 1A regulated general purpose boxed PSU |
77.96 |
|
BF377 |
24V 2A unregulated door release boxed PSU |
66.21 |
|
BF368EN |
24V 3A regulated boxed PSU to EN54/4 |
175.00 |
|
BF375PE |
24V 250mA unregulated double gang door release PSU c/w detector
circuit |
46.35 |
|
BF375PEK |
24V 250mA double gang automatic door release system |
186.15 |
|
|
Includes 1 x BF375PE double gang door release PSU c/w detector
circuit kit, 2 x Apollo C60 optical detector bases |
|
|
|
and 1 x electromagnetic door retainer |
|
|
BF345/1H |
24V d.c electromagnetic door retainer |
43.12 |
|
BF345/2H |
240V a.c electromagnetic door retainer |
42.82 |
|
|
|
|
|
24V BATTERY PACKS |
|
|
BC283/2 |
24V 1.2 Ahr VRLA battery pack (2 x 12V including link wire) |
25.72 |
|
BC284/2 |
|